BELT DRIVE POWER UNITS
MAINTENANCE MADE EASY
With Delaware Elevator Manufacturing's belt drive design, maintaining your power unit has never been easier.
DESIGNED TO MEET ANY SPECIFICATION
The DEM belt drive power unit can be adapted to meet nearly any special circumstances your particular project may involve.
STANDARD EQUIPMENT
- Motors: 15-100HP 3PH
- IMO Pumps: 43-425 GPM Single
- Pump. Transferable Oil up to 250 Gal.
- Tandem Pumps/Motors up to 200HP/850GPM
- EECO or maxton standard
- Valve Mounted in the Tank for Easy Stand-up Adjusting
- 12 ga. Formed Tank & Body
- Effective Easy Belt Adjustment
- Noise Reducing Muffler
- Isolated Pump/Motor Bedplate
- Protective Packaging
- Shut Off(Ball) Valve in the Tank
- Oil Level Sight Gauge
OPTIONS
- Blain Valve
- Constant Down Speed Valves
- Custom Tank Sizes
- Low Pressure Switch
- Low Oil Switch
- Tank Heater
- Oil Cooler
- Oil Return Pump
- 120 Starts Per Hour Motors
- DEM can meet your custom needs, call if requested options are not listed above.
HP
Volt
Full Load Amps
Locked Rotor Apms
( Wye-Delta )
50
230-460
119/60
244/122
60
230-460
143/72
304/152
75
230-460
180/90
370/185
100
230-460
228/114
524/262
Locked Rotor AMPS are given for Wye-Delta starting. Starting AMPS are 3 times Locked Rotor AMPS when starting across the line.
All motors also available in 575V & 380V/3PH/50Hz